How to size a pool heater
A pool heater has two jobs. It has to warm the water from cold, and while it does that, and afterwards, it has to replace the heat the pool keeps losing through its surface. Most rules of thumb look at only one of the two. This calculator works out both:
- Heat to warm the water. One BTU warms one pound of water by 1°F, and a gallon weighs about 8.33 lb.
- Heat lost through the surface. Evaporation, warm water meeting cooler air (convection) and heat radiating to the sky, per square foot, at your water and air temperatures, humidity and wind.
- Heater output. The output that does the first while covering the second, worked out degree by degree as the water warms, because a warmer pool loses heat faster.
Heat to warm the water (BTU) = gallons × 8.33 × temperature rise (°F)
Surface loss (BTU per sq ft per hour) = (63.6 + 32 V)(Pw − Pdp) + (0.5 + 0.235 V)(Tw − Ta) + 1.0 × (Tw − Ta)
Gas heater input = output ÷ efficiency
In the loss formula, V is the wind in mph, Tw and Ta are the water and air temperatures in °F, and Pw and Pdp are the water vapor pressures (in inches of mercury) at the water temperature and in the air. The three parts are evaporation, convection and radiation, as in the pool energy model ENERGY STAR uses, with its activity factor set to 1 for a quiet pool. Swimmers splash and add to evaporation while they swim, so a busy pool loses more.
Worked example
A 16 × 32 ft pool (512 sq ft) holds 20,000 gallons. The owner wants it warmed from 65°F to 80°F in 24 hours, on days averaging 60°F with 50% humidity and a 3.5 mph breeze, with no cover.
- Heat to warm the water: 20,000 × 8.33 × 15 = 2,499,000 BTU.
- Heat lost at 80°F: evaporation 135.2 + convection 26.5 + radiation 20.0 = 181.7 BTU per sq ft per hour, or about 93,000 BTU an hour for 512 sq ft. At 65°F the loss is only 74.9 per sq ft, which is why the calculator works through each degree.
- Output that does both in 24 hours: about 170,900 BTU an hour.
- Gas heater at 82% efficiency: 170,900 ÷ 0.82 = 208,400 BTU input, so a 250,000 BTU heater, the next common size up. With a cover on at night, 179,000 BTU would do.
Heater size by pool size
Gas heater input needed to warm the pool from 65°F to 80°F in 24 hours, at 60°F air, 50% humidity and a 3.5 mph wind, at 82% efficiency. The pools average 4½ to 5½ ft deep.
| Pool | Surface | No cover | Cover on at night | Heat lost at 80°F |
|---|---|---|---|---|
| 10,000 gal | 300 sq ft | 112,000 BTU | 94,000 BTU | 55,000 BTU/h |
| 15,000 gal | 450 sq ft | 168,000 BTU | 141,000 BTU | 82,000 BTU/h |
| 20,000 gal | 512 sq ft | 209,000 BTU | 179,000 BTU | 93,000 BTU/h |
| 25,000 gal | 648 sq ft | 262,000 BTU | 224,000 BTU | 118,000 BTU/h |
| 32,000 gal | 800 sq ft | 331,000 BTU | 284,000 BTU | 145,000 BTU/h |
Colder or windier weather, a faster heat-up or a warmer target all need more. Enter your own numbers above.
How long does it take to heat a pool?
It depends on the heater's output and how fast the pool loses heat. For the 20,000-gallon, 512 sq ft pool above (65°F to 80°F, 60°F air):
| Gas heater input | No cover | Cover on at night |
|---|---|---|
| 150,000 BTU | 46 hours | 31 hours |
| 200,000 BTU | 26 hours | 20 hours |
| 250,000 BTU | 18 hours | 15 hours |
| 300,000 BTU | 14 hours | 12 hours |
| 400,000 BTU | 9.5 hours | 8.7 hours |
Heat pumps are slower. The same pool warmed from 70°F to 82°F on 70°F days (60% humidity):
| Heat pump (80°F rating) | No cover | Cover on at night |
|---|---|---|
| 65,000 BTU | Stops at about 77°F | 4 days |
| 100,000 BTU | 3 days | 38 hours |
| 140,000 BTU | 31 hours | 23 hours |
A heater that is too small for the weather does not just take longer: the pool stops warming at the point where it loses heat as fast as the heater adds it. That is the usual reason a heat pump "runs all day but the pool won't go past 77". A cover, or a bigger heater, moves that point up. Enter the heater you have under Check a heater you have to see its time and its limit.
Gas heater or heat pump?
- Gas and propane heaters are sold by input, from about 100,000 to 400,000 BTU for homes. They heat fast in any weather, which suits pools heated now and then. Federal rules require at least 82% thermal efficiency. A gas heater is often limited by the gas line and meter: ask your installer or gas company what they can supply.
- Heat pumps move heat from the air, so they deliver about 4 to 6 times the electricity they use (a COP of 4 to 6) at 50 to 80°F air. They are rated at 80°F air (80/80/80), and their output falls as the air cools: on the spec sheets we checked, about 61% of that rating at 50°F air. Below about 50°F many slow to a crawl or stop. They suit pools kept warm through the season, with a cover.
The US Department of Energy's example puts a heat pump with a COP of 5 at about 70% of a gas heater's yearly running cost, but it compares against an old 55%-efficient gas heater, so with today's 82% models and your own prices the gap can close or reverse. The calculator works out both from your prices.
What it costs to heat a pool
The calculator shows two costs: warming the pool once, and keeping it warm for a day. For the example pool with natural gas at $1.50 a therm, warming it once costs about $75. Keeping it at 80°F on a 60°F day with no sun costs about $41 a day uncovered and $26 with a cover on at night. A heat pump at 18 cents a kWh would keep it warm for about $26 a day uncovered.
The daily figure assumes no sun, so it is a worst case: an outdoor pool absorbs most of the sunshine that falls on it, and a sunny day can supply a large share of the heat. The cheapest heat is the heat you keep:
- Cover the pool whenever nobody is swimming. Evaporation is the biggest heat loss, a cover stops up to 95% of it, and the Department of Energy puts the savings at 50 to 70%.
- Keep it cooler. Each degree warmer costs about 10 to 30% more to heat. Most heated pools sit at 78 to 82°F.
- Block the wind with a fence or hedge; wind speeds up evaporation.
- Turn it down when you are away. It does not take more energy to reheat than you save while it is off.
Rules of thumb, and why the results differ
| Rule | Example pool | What it leaves out |
|---|---|---|
| Surface area × (target − average air temperature) × 12 (US DOE) | 122,900 BTU/h output | Pool volume and heat-up time; assumes 3.5 mph wind |
| Surface area ÷ 3 × 1,000 (minimum) | 170,700 BTU | Weather, target and volume |
| 5 BTU per gallon at 60°F air, 4 at 70°F (heat pumps) | 100,000 BTU | Surface area and weather |
Each rule is a fair starting point for the conditions it was built on. The surface-area rules come closest because heat is lost through the surface. The calculator replaces them with your own pool and weather, and shows the arithmetic under the result.
Pool heater questions
What size heater do I need for a 20,000-gallon pool?
About 209,000 BTU of gas input to warm a typical 512 sq ft, 20,000-gallon pool by 15°F in a day at 60°F air, so a 250,000 BTU heater. Surface area and weather matter more than gallons, so enter yours above. For a heat pump, size for the weather you will swim in: the rating has to hold up at your air temperature.
Is a bigger pool heater better?
A bigger gas heater warms the pool faster and uses no more gas to put in the same heat; a shorter heat-up even loses a little less on the way. The limits are the price, the gas supply and the heater's flow needs. An undersized heat pump is the more common mistake: in cool weather it may never reach the target.
How many degrees a day can a heater raise a pool?
Divide the heater's output, less the pool's heat loss, by the gallons × 8.33. For the example pool, a 250,000 BTU gas heater adds about 1°F an hour at first and slows as the water warms. A 100,000 BTU heat pump on a 70°F day adds about 8°F a day at first, uncovered, slowing as the water warms: about 4°F a day on average from 70°F to 82°F.
Should I run the heater all the time or only before swimming?
The Department of Energy notes that it is a myth that reheating uses more energy than you save by turning the heater down. For a gas heater used now and then, heat up before swimming. Heat pumps are slow, so they are usually left to hold the temperature through the season, with the pool covered.
Does a solar cover really help a heater?
Yes. In the example, a cover on just at night cuts the cost of keeping the pool warm by about a third and makes the heat-up faster. On all the time when nobody swims, it saves more.
Sources
- Surface heat loss (evaporation, convection and radiation formulas, activity factor 1): ENERGY STAR technical reference, Swimming pools; checked against measurements: measured evaporation from quiet pools was 72% (near-calm) to 82% (5 mph) of the older ASHRAE formula on an outdoor pool in Colorado (Smith, Löf and Jones, Solar Energy, 1994), and 74% on quiet indoor and outdoor pools, with swimmers adding 40 to 70%: Smith, Löf and Jones, Rates of evaporation from swimming pools in active use (OSTI); the ENERGY STAR formula gives about 70 to 80% of the ASHRAE figure at 1 to 5 mph
- 1 BTU per pound per °F and 8.3 lb per gallon in the heat-up formula: AQUA Magazine, How to size a pool heater and US EIA, British thermal units; 1,048 BTU carried off by each pound of 80°F water that evaporates: US DOE, Swimming pool covers
- Covers stop up to 95% of evaporation: EPA WaterSense, Pool water efficiency; 50 to 70% heating savings: US DOE, Swimming pool covers (above)
- Surface area × rise × 12, heat pump COP of 3 to 7, rating at 80°F air and 80°F water, and the cost comparison: US DOE, Heat pump swimming pool heaters; 78 to 82°F, 10 to 30% per degree, and the reheating myth: US DOE, Managing swimming pool temperature
- Heat pump output and COP at 80/80/80, 80/63/80 and 50/63/80 (AHRI 1160): Hayward HeatPro 100K, Hayward HeatPro Low Ambient, Pentair UltraTemp catalog and Nirvana NE series; lowest heating air temperature of 40 to 50°F: the Hayward sheets
- 82% minimum thermal efficiency for gas pool heaters: AHRI, pool heater standards (10 CFR 430.32(k)) and Appliance Standards Awareness Project; residential gas heaters up to about 400,000 BTU: AQUA Magazine (above)
- Rules of thumb: surface ÷ 3 × 1,000 and surface × rise × 12: Leslie's, How to size a pool heater; 4 to 5 BTU per gallon by air temperature: HVACDirect sizing guide; gas line and meter limits: Trouble Free Pool
- Energy prices: natural gas US EIA, residential natural gas prices and 1,037 BTU per cubic foot US EIA FAQ; propane US EIA heating oil and propane update; electricity US EIA Electric Power Monthly, table 5.3
Last checked November 23, 2026. These are estimates for home pools; real heat loss changes with sun, shade, wind and swimmers. A pool professional can size a heater for your site, and the heater's own manual comes first.
Related calculators
- Pool Volume CalculatorHow many gallons your pool holds. Any shape, sloped or hopper floors, above-ground pools.
- Pool Chemical CalculatorAll your test results at once: every dose, in the right order.
- Pool Salt CalculatorHow much salt to add, in pounds and bags, for your generator's target. Too high? How much water to replace.
- Pool Chlorine CalculatorHow much liquid chlorine, bleach or granules to add, with a target set by your stabilizer (CYA) level.
- Pool Shock CalculatorHow many bags of shock or jugs of liquid chlorine, for a routine shock or to clear algae at the level your CYA needs.
- Pool Stabilizer CalculatorHow much granular or liquid stabilizer to add, or how much water to drain when CYA is too high.
- Pool Alkalinity CalculatorHow much baking soda raises total alkalinity, or how much acid lowers it, in safe rounds.
- Pool pH and Muriatic Acid CalculatorHow much muriatic acid lowers pH, or soda ash raises it, for your alkalinity.
- Pool LSI CalculatorSaturation index (LSI or CSI) from your test results, at any temperature, with the dose to fix it.
- Pool Pump Size CalculatorThe flow and head your pump must deliver, with pipe and filter limits and variable-speed settings.
- Pool Filter Size CalculatorFilter area for cartridge, sand or DE from your gallons and pump flow, plus a check of the filter you have.
- Pool Evaporation CalculatorDaily water loss in inches and gallons for your weather, and a check of your measured drop for a leak.
- Hot Tub Chemical CalculatorChlorine or bromine, pH, alkalinity and calcium for your hot tub, in teaspoons and in order.