CalcMyPool

Pool Heater Size Calculator

Find the gas heater or heat pump size your pool needs to warm up in the time you want, then keep it warm. The calculator counts the heat your pool loses to evaporation, air and sky at your weather, so it also tells you how long a heater you already have will take, and what heating costs a day.

Heater type

Length × width for a rectangle. Heat escapes through the surface, so this matters more than the gallons.

Not sure? The pool volume calculator works it out and saves it for every calculator here.

Most heated pools are kept at 78 to 82°F.

The coolest daily average (day and night) you plan to heat in, with its usual humidity. Cooler, drier air means a bigger heater.

Wind right at the water: the US Department of Energy's sizing rule assumes 3.5 mph (5.6 km/h). Use less for a fenced, sheltered pool. Heat-up time: gas heaters are usually sized to warm a pool in about a day; heat pumps take longer.

Pool cover

On at night means covered 12 hours a day. A cover stops up to 95% of evaporation, the biggest heat loss.

Check a heater you have

The BTU figure in the model name or on the rating plate, such as 250,000. The result shows how long it takes and how warm it can get.

Efficiency and energy price
Fuel

82% is the federal minimum for gas pool heaters in the US; check your heater's manual. Use the rate on your bill, per therm; US average prices run higher in summer months.

Heater size you need

209,000 BTU gas input

Warms 20,000 gallons from 65°F to 80°F in 24 hours at 60°F air, 50% humidity, 3.5 mph wind, uncovered, with no help from the sun.

  • $75.02to heat up once
  • $40.84a day to keep it warm
  • 93,000 BTU/hheat lost at target

What to do

  1. Choose a gas heater with an input rating of at least 209,000 BTU. Gas heaters are sold by input: at 82% efficiency it puts about 170,900 BTU/h into the water. If your gas line or meter cannot supply that much, a smaller heater works only slower, as long as it is well above 114,000 BTU, the input that just holds 80°F in this weather. Try one under Check a heater you have.
  2. Once it is warm, the pool loses about 93,000 BTU/h at 60°F air. The heater only has to replace that, so it runs part of the time. Sun in the day cuts this a lot; the figures here assume none.
  3. Cover it at night. Keeping it warm would cost about $26.40 a day instead of $40.84: evaporation is the biggest heat loss, and a cover stops most of it.
  4. A bigger heater does not use more gas to put in the same heat. It gets there sooner, and a shorter heat-up loses less heat on the way.
  5. Every heater needs a minimum flow from the pump. Check it with the pool pump size calculator.

How it was worked out

Heat to warm the water = 20,000 gal × 8.33 lb × 15°F = 2,499,000 BTU. Heat lost at 80°F water, 60°F air, 50% humidity and 3.5 mph wind (ENERGY STAR pool model): evaporation 135.2 + convection 26.5 + radiation 20 = 181.7 BTU per sq ft per hour × 512 sq ft = 93,024 BTU/h. The heater output that warms the pool in 24 hours while it loses heat (worked degree by degree as the water warms) is 170,880 BTU/h. Gas input = 170,880 ÷ 0.82 = 208,391 BTU/h. Fuel = BTU ÷ 0.82 ÷ 100,000 BTU per therm.

How to size a pool heater

A pool heater has two jobs. It has to warm the water from cold, and while it does that, and afterwards, it has to replace the heat the pool keeps losing through its surface. Most rules of thumb look at only one of the two. This calculator works out both:

  1. Heat to warm the water. One BTU warms one pound of water by 1°F, and a gallon weighs about 8.33 lb.
  2. Heat lost through the surface. Evaporation, warm water meeting cooler air (convection) and heat radiating to the sky, per square foot, at your water and air temperatures, humidity and wind.
  3. Heater output. The output that does the first while covering the second, worked out degree by degree as the water warms, because a warmer pool loses heat faster.

Heat to warm the water (BTU) = gallons × 8.33 × temperature rise (°F)
Surface loss (BTU per sq ft per hour) = (63.6 + 32 V)(Pw − Pdp) + (0.5 + 0.235 V)(Tw − Ta) + 1.0 × (Tw − Ta)
Gas heater input = output ÷ efficiency

In the loss formula, V is the wind in mph, Tw and Ta are the water and air temperatures in °F, and Pw and Pdp are the water vapor pressures (in inches of mercury) at the water temperature and in the air. The three parts are evaporation, convection and radiation, as in the pool energy model ENERGY STAR uses, with its activity factor set to 1 for a quiet pool. Swimmers splash and add to evaporation while they swim, so a busy pool loses more.

Worked example

A 16 × 32 ft pool (512 sq ft) holds 20,000 gallons. The owner wants it warmed from 65°F to 80°F in 24 hours, on days averaging 60°F with 50% humidity and a 3.5 mph breeze, with no cover.

  • Heat to warm the water: 20,000 × 8.33 × 15 = 2,499,000 BTU.
  • Heat lost at 80°F: evaporation 135.2 + convection 26.5 + radiation 20.0 = 181.7 BTU per sq ft per hour, or about 93,000 BTU an hour for 512 sq ft. At 65°F the loss is only 74.9 per sq ft, which is why the calculator works through each degree.
  • Output that does both in 24 hours: about 170,900 BTU an hour.
  • Gas heater at 82% efficiency: 170,900 ÷ 0.82 = 208,400 BTU input, so a 250,000 BTU heater, the next common size up. With a cover on at night, 179,000 BTU would do.

Heater size by pool size

Gas heater input needed to warm the pool from 65°F to 80°F in 24 hours, at 60°F air, 50% humidity and a 3.5 mph wind, at 82% efficiency. The pools average 4½ to 5½ ft deep.

PoolSurfaceNo coverCover on at nightHeat lost at 80°F
10,000 gal300 sq ft112,000 BTU94,000 BTU55,000 BTU/h
15,000 gal450 sq ft168,000 BTU141,000 BTU82,000 BTU/h
20,000 gal512 sq ft209,000 BTU179,000 BTU93,000 BTU/h
25,000 gal648 sq ft262,000 BTU224,000 BTU118,000 BTU/h
32,000 gal800 sq ft331,000 BTU284,000 BTU145,000 BTU/h

Colder or windier weather, a faster heat-up or a warmer target all need more. Enter your own numbers above.

How long does it take to heat a pool?

It depends on the heater's output and how fast the pool loses heat. For the 20,000-gallon, 512 sq ft pool above (65°F to 80°F, 60°F air):

Gas heater inputNo coverCover on at night
150,000 BTU46 hours31 hours
200,000 BTU26 hours20 hours
250,000 BTU18 hours15 hours
300,000 BTU14 hours12 hours
400,000 BTU9.5 hours8.7 hours

Heat pumps are slower. The same pool warmed from 70°F to 82°F on 70°F days (60% humidity):

Heat pump (80°F rating)No coverCover on at night
65,000 BTUStops at about 77°F4 days
100,000 BTU3 days38 hours
140,000 BTU31 hours23 hours

A heater that is too small for the weather does not just take longer: the pool stops warming at the point where it loses heat as fast as the heater adds it. That is the usual reason a heat pump "runs all day but the pool won't go past 77". A cover, or a bigger heater, moves that point up. Enter the heater you have under Check a heater you have to see its time and its limit.

Gas heater or heat pump?

  • Gas and propane heaters are sold by input, from about 100,000 to 400,000 BTU for homes. They heat fast in any weather, which suits pools heated now and then. Federal rules require at least 82% thermal efficiency. A gas heater is often limited by the gas line and meter: ask your installer or gas company what they can supply.
  • Heat pumps move heat from the air, so they deliver about 4 to 6 times the electricity they use (a COP of 4 to 6) at 50 to 80°F air. They are rated at 80°F air (80/80/80), and their output falls as the air cools: on the spec sheets we checked, about 61% of that rating at 50°F air. Below about 50°F many slow to a crawl or stop. They suit pools kept warm through the season, with a cover.

The US Department of Energy's example puts a heat pump with a COP of 5 at about 70% of a gas heater's yearly running cost, but it compares against an old 55%-efficient gas heater, so with today's 82% models and your own prices the gap can close or reverse. The calculator works out both from your prices.

What it costs to heat a pool

The calculator shows two costs: warming the pool once, and keeping it warm for a day. For the example pool with natural gas at $1.50 a therm, warming it once costs about $75. Keeping it at 80°F on a 60°F day with no sun costs about $41 a day uncovered and $26 with a cover on at night. A heat pump at 18 cents a kWh would keep it warm for about $26 a day uncovered.

The daily figure assumes no sun, so it is a worst case: an outdoor pool absorbs most of the sunshine that falls on it, and a sunny day can supply a large share of the heat. The cheapest heat is the heat you keep:

  • Cover the pool whenever nobody is swimming. Evaporation is the biggest heat loss, a cover stops up to 95% of it, and the Department of Energy puts the savings at 50 to 70%.
  • Keep it cooler. Each degree warmer costs about 10 to 30% more to heat. Most heated pools sit at 78 to 82°F.
  • Block the wind with a fence or hedge; wind speeds up evaporation.
  • Turn it down when you are away. It does not take more energy to reheat than you save while it is off.

Rules of thumb, and why the results differ

RuleExample poolWhat it leaves out
Surface area × (target − average air temperature) × 12 (US DOE)122,900 BTU/h outputPool volume and heat-up time; assumes 3.5 mph wind
Surface area ÷ 3 × 1,000 (minimum)170,700 BTUWeather, target and volume
5 BTU per gallon at 60°F air, 4 at 70°F (heat pumps)100,000 BTUSurface area and weather

Each rule is a fair starting point for the conditions it was built on. The surface-area rules come closest because heat is lost through the surface. The calculator replaces them with your own pool and weather, and shows the arithmetic under the result.

Pool heater questions

What size heater do I need for a 20,000-gallon pool?

About 209,000 BTU of gas input to warm a typical 512 sq ft, 20,000-gallon pool by 15°F in a day at 60°F air, so a 250,000 BTU heater. Surface area and weather matter more than gallons, so enter yours above. For a heat pump, size for the weather you will swim in: the rating has to hold up at your air temperature.

Is a bigger pool heater better?

A bigger gas heater warms the pool faster and uses no more gas to put in the same heat; a shorter heat-up even loses a little less on the way. The limits are the price, the gas supply and the heater's flow needs. An undersized heat pump is the more common mistake: in cool weather it may never reach the target.

How many degrees a day can a heater raise a pool?

Divide the heater's output, less the pool's heat loss, by the gallons × 8.33. For the example pool, a 250,000 BTU gas heater adds about 1°F an hour at first and slows as the water warms. A 100,000 BTU heat pump on a 70°F day adds about 8°F a day at first, uncovered, slowing as the water warms: about 4°F a day on average from 70°F to 82°F.

Should I run the heater all the time or only before swimming?

The Department of Energy notes that it is a myth that reheating uses more energy than you save by turning the heater down. For a gas heater used now and then, heat up before swimming. Heat pumps are slow, so they are usually left to hold the temperature through the season, with the pool covered.

Does a solar cover really help a heater?

Yes. In the example, a cover on just at night cuts the cost of keeping the pool warm by about a third and makes the heat-up faster. On all the time when nobody swims, it saves more.

Sources

Last checked November 23, 2026. These are estimates for home pools; real heat loss changes with sun, shade, wind and swimmers. A pool professional can size a heater for your site, and the heater's own manual comes first.

Related calculators

Heater size209,000 BTU