Work out how much baking soda raises total alkalinity (TA) to the right level for your pool, or how much muriatic or dry acid lowers it. Add your pH and it also estimates what the dose does to pH and splits a big acid dose into safe rounds.

Not sure? Work it out with the pool volume calculator, then come back.

Chlorine you use

Liquid chlorine, bleach or cal-hypo. Target 80 ppm: inside the 80 to 100 that the pool industry's water quality committee (PHTA) gives for these chlorines, and Trouble Free Pool's 50 to 90.

From a drop kit if you can: with a 25 mL sample, each drop of titrant is 10 ppm. Strips are rough for TA.

Fine for this pool: 60 to 100 ppm.

With your pH the calculator shows what the dose does to pH and, when lowering, how much acid to add in each round. CYA makes that estimate closer.

Total alkalinity

–

  • –change
  • 80 ppmtarget
  • –pH right after

How it was worked out

To see the result, enter your TA reading.

How much baking soda raises alkalinity

Total alkalinity is the water's buffer: it soaks up acid and keeps pH from swinging. Too low, and pH jumps around and can etch plaster and metal; too high, and pH keeps drifting up and scale gets easier. To raise it, add sodium bicarbonate: plain baking soda, which is exactly what "alkalinity increaser" is. Alkalinity is counted as if it were calcium carbonate, and 84.01 g of baking soda adds as much as 50.04 g of that, so:

Pounds of baking soda = gallons × ppm to raise × 8.345 ÷ 1,000,000 × 1.679
Grams of baking soda = liters × ppm to raise ÷ 1,000 × 1.679

Example: a 15,000-gallon pool at 70 ppm, raised to 100 ppm, needs 15,000 × 30 × 8.345 ÷ 1,000,000 × 1.679 = 6.3 lb of baking soda. That works out to 1.40 lb per 10,000 gallons for each 10 ppm, the figure in Inyo's dosing table. Most labels round it up to 1.5 lb, so a label dose lands slightly above your target.

Doses per 10,000 gallons

Change TA byBaking soda (raise)Muriatic acid 31.45% (lower)Dry acid 93.2% (lower)
10 ppm1.40 lb25.6 fl oz2.15 lb
20 ppm2.80 lb51.3 fl oz4.30 lb
30 ppm4.20 lb76.9 fl oz (0.60 gal)6.45 lb
40 ppm5.60 lb103 fl oz (0.80 gal)8.59 lb

Acid amounts are totals: lower TA in rounds, as explained below. Half-strength acid (14.5%) takes 60.1 fl oz per 10 ppm, about 2.3 times as much. Labels vary: one muriatic label we checked says 2 cups (16 fl oz) per 10 ppm. The calculator works from the acid's strength, which agrees with AQUA Magazine's 25.6 fl oz.

For a big raise, add about half, run the pump, test again after about 6 hours, and work out the rest from the new reading. Broadcast it over the deep end with the pump running; a short cloudiness is normal. Baking soda moves pH only gently, toward about 8.3, so with your pH entered the calculator shows the pH to expect right after.

The right alkalinity for your pool

Chlorine you useTrouble Free PoolStandards and makersCalculator's target
Liquid chlorine, bleach, cal-hypo60 to 80 ideal (50 to 90 fine)80 to 100 (PHTA committee)80
Salt chlorine generator60 to 80 ideal (50 to 90 fine)80 to 100 (PHTA committee); 80 to 120 (Hayward, Pentair manuals)80
Tablets (trichlor) or dichlornot listed separately100 to 120 (PHTA committee)100

The pool industry's water quality committee (PHTA) explains the split: liquid chlorine, cal-hypo and salt generators push pH up, so they need less buffer; tablets and dichlor push it down and slowly eat alkalinity, so they need more. In salt pools higher TA makes pH climb faster, which is why Trouble Free Pool aims lower than the generator manuals. The calculator suggests 80, a level inside every range for liquid chlorine and salt. Pool codes and ANSI/APSP-11 set the outer limits at 60 and 180 ppm. Your pool's surface (plaster, vinyl or fiberglass) matters for calcium and the saturation index, not for this target.

How to lower alkalinity: acid and air

Short of draining and refilling, acid is the only way to lower TA, and it lowers pH at the same time. Air does the opposite half of the job: bubbling and splashing drive carbon dioxide out of the water, which raises pH without changing TA. So TA is lowered in rounds:

  1. Add acid until pH is about 7.0 (Trouble Free Pool says 7.0 to 7.2). This also lowers TA. Add it in portions no bigger than your label allows at one time (one muriatic label we checked: 16 fl oz per 10,000 gallons), and wait at least 30 minutes with the pump running before re-testing pH.
  2. Aerate until pH is back to about 7.6: point the return jets up at the surface, run waterfalls, fountains or a spa spillover, and run the pump on high.
  3. Repeat until TA reaches your target. Test pH before each round and TA every round or two.

Example: 15,000 gallons at TA 150 and pH 7.8, with 40 ppm CYA, down to 80 ppm, takes 269 fl oz (2.1 gallons) of 31.45% muriatic acid in total. Poured all at once it would drop pH to about 6.4. In rounds it is about 90 fl oz, in portions, to reach pH 7.0 (TA about 127), then 68, 60 and 51 fl oz, each after aerating back to 7.6. Each round takes less, because there is less buffer left. The calculator does this for your numbers.

The round sizes come from a model of the water's carbonate buffer, using standard equilibrium constants for your water and counting the part of TA that comes from CYA. The model matches AQUA Magazine's worked case of the same problem: lowering TA from 200 to 80 ppm at once, from pH 7.8 with 30 ppm CYA, drops pH to about 6.1. It is an estimate for the moment the acid mixes in, so go by your test before each round.

  • The "acid in one spot" trick does not lower TA more. Pouring acid in one place without circulation is an old method, but TA falls by the same amount however the acid goes in; only the amount matters. Pour it slowly in front of a return jet with the pump running.
  • No hurry? Bringing pH back to 7.2 each time it reaches 7.8 lowers TA over time with no extra work.
  • It comes back? If your fill water is high in alkalinity, every top-up adds some back. Keep pH in range and lower TA only as far as you need.

Muriatic or dry acid?

Muriatic acid (hydrochloric acid, usually 31.45%) is the cheaper option and the usual choice for salt pools. It fumes, so wear gloves and eye protection and stand upwind; if the label says to dilute it, add acid to a bucket of water, never water to acid. Dry acid (sodium bisulfate, pH down) is easier to store and handle but costs more, and it adds sulfates, which can damage plaster and salt cell plates, so Trouble Free Pool advises against it in plaster pools and pools with a salt generator. Store any acid away from chlorine: mixed, they release chlorine gas.

Why alkalinity keeps changing

  • Low TA with pH that keeps rising is common in salt pools. Raising TA makes pH climb faster, so the acid you then add to hold pH lowers TA again. Many salt pools settle at a TA where pH is steadier; if yours holds pH at 60 to 70 ppm, that is fine.
  • Falling TA: acid you add for pH, tablets and dichlor, and rain all wear it down.
  • Rising TA: fill water with high alkalinity, and baking soda or soda ash.

The CYA part of your TA reading

The TA test counts cyanurate as well as carbonate, so stabilizer adds to the reading: about a third of your CYA at pH 7.4 to 7.8 (the correction factor is 0.31 at pH 7.4 and about 0.35 at 7.8). Water-balance numbers such as the saturation index use the corrected (carbonate) alkalinity: TA minus that share. For the doses on this page no correction is needed, because baking soda and acid change the test reading one for one; the calculator uses your CYA only for the pH estimates.

Frequently asked questions

Is baking soda the same as alkalinity increaser?

Yes. Alkalinity increaser is sodium bicarbonate, and so is plain baking soda; grocery-store baking soda works the same and usually costs less. Soda ash (sodium carbonate, pH up) is a different chemical: for the same rise in TA it pushes pH up far more.

Should I adjust alkalinity or pH first?

Usually alkalinity, because it sets how much the pH moves when you add anything. The exception is lowering: acid lowers both, so you lower TA through pH, in rounds.

How soon can I swim after adjusting alkalinity?

Follow your product's label. The labels we checked, for a baking soda product and for a dry acid, allow swimming after about 4 hours of circulation.

Does aeration lower alkalinity?

No. Aeration raises pH and leaves TA unchanged. It is useful because it lets you add more acid, which is what lowers TA, without pH falling too far.

How do I test total alkalinity?

With a drop kit: fill the tube to 25 mL, add the reagents, then count drops of titrant until the color changes from green to red. Each drop is 10 ppm, so 8 drops means 80 ppm. If TA is very high, Taylor's method is a 10 mL sample with each drop counting 25 ppm.

Sources

Last checked November 23, 2026. Always follow the label on your chemicals.

Related calculators